Access the full text.
Sign up today, get DeepDyve free for 14 days.
R. Ganz, U. Lüthi, B. Rahn, S. Perren (1981)
[Intra-articular pressure rise influencing epiphyseal blood circulation. An experimental model (author's transl)].Der Orthopade, 10 1
P. Tothill (1984)
Bone blood flow measurement.Journal of biomedical engineering, 6 4
S. Hellem, L. Jacobsson, G. Nilsson, D. Lewis (1983)
Measurement of microvascular blood flow in cancellous bone using laser Doppler flowmetry and 133Xe-clearance.International journal of oral surgery, 12 3
G. Buckberg, J. Luck, D. Payne, J. Hoffman, J. Archie, D. Fixler (1971)
Some sources of error in measuring regional blood flow with radioactive microspheres.Journal of applied physiology, 31 4
Hellem Hellem, Jacobsson Jacobsson, Nilsson Nilsson (1983)
Microvascular response in cancellous bone to experimental halothane induced hypotension in pigsInt J Oral Surg, 12
(1963)
Alterations in the in-traarticular pressures in transcervical fractures
P. Gross, M. Marcus, D. Heistad (1981)
Measurement of blood flow to bone and marrow in experimental animals by means of the microsphere technique.The Journal of bone and joint surgery. American volume, 63 6
L. Whiteside, P. Lesker, D. Simmons (1977)
Measurement of regional bone and bone marrow blood flow in the rabbit using the hydrogen washout technique.Clinical orthopaedics and related research, 122
S. Hellem, L. Jacobsson, G. Nilsson (1983)
Microvascular response in cancellous bone to halothane-induced hypotension in pigs.International journal of oral surgery, 12 3
Schoenecker Schoenecker, Bitz Bitz, Whiteside Whiteside (1978)
The acute effect of position of immobilization on capital femoral epiphyseal blood flowJ Bone Joint Surg (Am), 60
Gwo‐Jaw Wang, S. Hubbard, S. Reger, E. Miller, W. Stamp (1983)
Femoral Head Blood Flow in Long‐Term Steroid Therapy: Study of Rabbit ModelSouthern Medical Journal, 76
Gert Nilsson, T. Tenland, P. Oberg (1980)
Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood FlowIEEE Transactions on Biomedical Engineering, BME-27
J. Drake, M. Meyers (1984)
Intracapsular Pressure and Hemarthrosis Following Femoral Neck FractureClinical Orthopaedics and Related Research, &NA;
G. Wang, S. Dughman, S. Reger, W. Stamp (1985)
The effect of core decompression on femoral head blood flow in steroid-induced avascular necrosis of the femoral head.The Journal of bone and joint surgery. American volume, 67 1
C. Woodhouse (1964)
Dynamic influences of vascular occlusion affecting the development of avascular necrosis of the femoral head.Clinical orthopaedics and related research, 32
P. Lunde, K. Michelsen (1970)
Determination of cortical blood flow in rabbit femur by radioactive microspheres.Acta physiologica Scandinavica, 80 1
P. Schoenecker, M. Bitz, L. Witeside (1978)
The acute effect of position of immobilization on capital femoral epiphyseal blood flow. A quantitative study using the hydrogen washout technique.The Journal of bone and joint surgery. American volume, 60 7
(1981)
Intraartikulare druckerhohung und epiphysare durchblutungsstorung
M. Heymann, B. Payne, J. Hoffman, A. Rudolph (1977)
Blood flow measurements with radionuclide-labeled particles.Progress in cardiovascular diseases, 20 1
Laser Doppler flowmetry (LDF) was used to measure bone blood flow in the rabbit femoral head and femoral condyles. To correlate the LDF output signal blood cell flux to in vivo blood flow, simultaneous measurements using LDF and 85Sr‐labeled microspheres were made in an adult rabbit model. There was no correlation between the two methods for blood flow in the femoral condyles and the correlation between the two methods for blood flow in the femoral head does not achieve statistical significance. An LDF signal of 0.4 V was approximately equal to a microsphere measured flow rate of 0.4 ml blood/g bone/min. The strength of the correlation in the latter case may have been affected by (a) large arteriovenous shunts, (b) inadequate mixing of the microspheres with a left ventricular injection, and (c) insufficient numbers of microspheres present in the bone samples with which to satisfy the mathematical requirements of the microsphere method. When LDF was used to evaluate the effect of elevated intracapsular pressure on femoral head blood flow in skeletally mature rabbits, femoral head subchondral bone blood flow declined with increasing intracapsular pressure from a baseline value of 0.343 ± 0.036 to a value of 0.127 ± 0.27 at 120 cm of water pressure. The decline in femoral head blood flow was statistically significant at pressures of 40 cm of water or higher (p < 0.001), and evaluation of sections of the proximal femora made from preterminal disulphine blue injections confirmed these findings. Intracapsular tamponade has an adverse effect on femoral head blood flow beginning well below central venous pressure and should be considered in the pathophysiology of posttraumatic and nontraumatic necrosis of the femoral head. Laser Doppler flowmetry was easy to use and appears to be a reproducible technique for evaluating femoral head blood flow, offering distinct advantages over the microsphere technique for measuring bone blood flow. Further studies of the in vivo calibration of the LDF method for bone blood flow are necessary for the method to have potential for clinical application.
Journal of Orthopaedic Research – Wiley
Published: Jan 1, 1986
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.