Access the full text.
Sign up today, get DeepDyve free for 14 days.
Alessandra Braccini, D. Wendt, C. Jaquiéry, M. Jakob, M. Heberer, Linda Kenins, A. Wodnar‐Filipowicz, R. Quarto, I. Martin (2005)
Three‐Dimensional Perfusion Culture of Human Bone Marrow Cells and Generation of Osteoinductive GraftsSTEM CELLS, 23
M. Montjovent, S. Mark, L. Mathieu, C. Scaletta, A. Scherberich, C. Delabarde, P. Zambelli, P. Bourban, L. Applegate, D. Pioletti (2008)
Human fetal bone cells associated with ceramic reinforced PLA scaffolds for tissue engineering.Bone, 42 3
S. Post, B. Abdallah, J. Bentzon, M. Kassem (2008)
Demonstration of the presence of independent pre-osteoblastic and pre-adipocytic cell populations in bone marrow-derived mesenchymal stem cells.Bone, 43 1
I. Martin, T. Smith, D. Wendt (2009)
Bioreactor-based roadmap for the translation of tissue engineering strategies into clinical products.Trends in biotechnology, 27 9
V. Sikavitsas, G. Bancroft, H. Holtorf, J. Jansen, A. Mikos (2003)
Mineralized matrix deposition by marrow stromal osteoblasts in 3D perfusion culture increases with increasing fluid shear forcesProceedings of the National Academy of Sciences of the United States of America, 100
R. Heary, R. Schlenk, Theresa Sacchieri, D. Barone, C. Brotea (2002)
Persistent Iliac Crest Donor Site Pain: Independent Outcome AssessmentNeurosurgery, 50
N. Datta, Quynh Pham, U. Sharma, V. Sikavitsas, J. Jansen, A. Mikos (2006)
In vitro generated extracellular matrix and fluid shear stress synergistically enhance 3D osteoblastic differentiation.Proceedings of the National Academy of Sciences of the United States of America, 103 8
Alessandra Braccini, D. Wendt, J. Farhadi, S. Schaeren, M. Heberer, I. Martin (2007)
The osteogenicity of implanted engineered bone constructs is related to the density of clonogenic bone marrow stromal cellsJournal of Tissue Engineering and Regenerative Medicine, 1
D. Wendt, A. Marsano, M. Jakob, M. Heberer, I. Martin (2003)
Oscillating perfusion of cell suspensions through three‐dimensional scaffolds enhances cell seeding efficiency and uniformityBiotechnology and Bioengineering, 84
B. Abdallah, N. Ditzel, M. Kassem (2008)
Assessment of bone formation capacity using in vivo transplantation assays: procedure and tissue analysis.Methods in molecular biology, 455
T. Bauer, G. Muschler (2000)
Bone graft materials. An overview of the basic science.Clinical orthopaedics and related research, 371
A. Papadimitropoulos, E. Piccinini, S. Brachat, Alessandra Braccini, D. Wendt, A. Barbero, C. Jacobi, I. Martin (2014)
Expansion of Human Mesenchymal Stromal Cells from Fresh Bone Marrow in a 3D Scaffold-Based System under Direct PerfusionPLoS ONE, 9
R. Izadpanah, D. Kaushal, C. Kriedt, F. Tsien, Bindiya Patel, J. Dufour, B. Bunnell (2008)
Long-term in vitro expansion alters the biology of adult mesenchymal stem cells.Cancer research, 68 11
Chantal Holy, Molly Shoichet, John Davies (2000)
Engineering three-dimensional bone tissue in vitro using biodegradable scaffolds: investigating initial cell-seeding density and culture period.Journal of biomedical materials research, 51 3
S. Scaglione, Alessandra Braccini, D. Wendt, C. Jaquiéry, Francesco Beltrame, R. Quarto, I. Martin (2006)
Engineering of osteoinductive grafts by isolation and expansion of ovine bone marrow stromal cells directly on 3D ceramic scaffoldsBiotechnology and Bioengineering, 93
A computer‐controlled perfusion bioreactor was developed for the streamlined production of engineered osteogenic grafts. This system automated the required bioprocesses, from the initial filling of the system through the phases of cell seeding and prolonged cell/tissue culture. Flow through chemo‐optic micro‐sensors allowed to non‐invasively monitor the levels of oxygen and pH in the perfused culture medium throughout the culture period. To validate its performance, freshly isolated ovine bone marrow stromal cells were directly seeded on porous scaffold granules (hydroxyapatite/β‐tricalcium‐phosphate/poly‐lactic acid), bypassing the phase of monolayer cell expansion in flasks. Either 10 or 20 days after culture, engineered cell‐granule grafts were implanted in an ectopic mouse model to quantify new bone formation. After four weeks of implantation, histomorphometry showed more bone in bioreactor‐generated grafts than cell‐free granule controls, while bone formation did not show significant differences between 10 days and 20 days of incubation. The implanted granules without cells had no bone formation. This novel perfusion bioreactor has revealed the capability of activation larger viable bone graft material, even after shorter incubation time of graft material. This study has demonstrated the feasibility of engineering osteogenic grafts in an automated bioreactor system, laying the foundation for a safe, regulatory‐compliant, and cost‐effective manufacturing process. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 532–537, 2016.
Journal of Biomedical Materials Research – Wiley
Published: Apr 1, 2016
Keywords: ; ; ; ; ;
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.