Ultrasound Tissue Characterization of Breast Biopsy Specimens

Ultrasound Tissue Characterization of Breast Biopsy Specimens Results of measurements of ultrasound speed and absorption coefficients in the range 3 to 8 MHz in breast tissues at 37 C are reported and analyzed in attempts to identify a set of ultrasound parameters capable of discriminating normal, benign, and malignant tissues. We analyzed 118 tissue regions, comprising 47 normal, 55 benign, and 16 malignant by straight-line fitting of frequency dependence of attenuation. Data for ten additional regions, for a total of 128, became available and were added to the cohort when we subsequently fitted quadratic curves. Sound speed consistently emerged as the variable with greatest discriminating power, particularly for separating normal from benign and malignant tissue. Great difficulty was encountered in discriminating benign from malignant, even when the jackknife technique was used. More success was found with classification and regression trees (CART), although results were sensitive to assigned misclassification costs. Best results from straight-line fits were obtained when discriminating malignant from combined normal/benign data after randomly assigning 75 percent of the data to the learning set and 25 percent to the test set. Then, 23 out of 25 normal/benign and 4 out of 4 malignant cases in the test set were correctly classified. With quadratic fitting, best results were obtained in the three-class case — the false positive rate for malignancy was reduced to zero in the learning (0/31) and test (0/10) sets. Nevertheless, the false negative rate increased to 13 out of 31 (42 percent) in the learning set, while attaining zero (0/4) in the test set. http://www.deepdyve.com/assets/images/DeepDyve-Logo-lg.png Ultrasonic Imaging SAGE

Loading next page...
 
/lp/sage/ultrasound-tissue-characterization-of-breast-biopsy-specimens-RU7QeWe52Q

References (23)

Publisher
SAGE
Copyright
© 1991 SAGE Publications
ISSN
0161-7346
eISSN
1096-0910
DOI
10.1177/016173469101300204
pmid
1650048
Publisher site
See Article on Publisher Site

Abstract

Results of measurements of ultrasound speed and absorption coefficients in the range 3 to 8 MHz in breast tissues at 37 C are reported and analyzed in attempts to identify a set of ultrasound parameters capable of discriminating normal, benign, and malignant tissues. We analyzed 118 tissue regions, comprising 47 normal, 55 benign, and 16 malignant by straight-line fitting of frequency dependence of attenuation. Data for ten additional regions, for a total of 128, became available and were added to the cohort when we subsequently fitted quadratic curves. Sound speed consistently emerged as the variable with greatest discriminating power, particularly for separating normal from benign and malignant tissue. Great difficulty was encountered in discriminating benign from malignant, even when the jackknife technique was used. More success was found with classification and regression trees (CART), although results were sensitive to assigned misclassification costs. Best results from straight-line fits were obtained when discriminating malignant from combined normal/benign data after randomly assigning 75 percent of the data to the learning set and 25 percent to the test set. Then, 23 out of 25 normal/benign and 4 out of 4 malignant cases in the test set were correctly classified. With quadratic fitting, best results were obtained in the three-class case — the false positive rate for malignancy was reduced to zero in the learning (0/31) and test (0/10) sets. Nevertheless, the false negative rate increased to 13 out of 31 (42 percent) in the learning set, while attaining zero (0/4) in the test set.

Journal

Ultrasonic ImagingSAGE

Published: Apr 1, 1991

There are no references for this article.