Access the full text.
Sign up today, get DeepDyve free for 14 days.
W. Wesselink, Dr. Holsheimer, H. Boom (1999)
A model of the electrical behaviour of myelinated sensory nerve fibres based on human dataMedical & Biological Engineering & Computing, 37
M. Kwan, E. Wall, J. Massie, S. Garfin (1992)
Strain, stress and stretch of peripheral nerve. Rabbit experiments in vitro and in vivo.Acta orthopaedica Scandinavica, 63 3
(2000)
Calculation of the Electrical Field Induced by Magnetic Coils in a Multiple Cylinder Volume Conductor
J. Desmedt (1981)
Motor unit types, recruitment and plasticity in health and disease
A. Vučković, N. Rijkhoff, J. Struijk (2004)
Different pulse shapes to obtain small fiber selective activation by anodal blocking-a simulation studyIEEE Transactions on Biomedical Engineering, 51
V. Schnabel, J. Struijk (1999)
Magnetic and electrical stimulation of undulating nerve fibres: a simulation studyMedical & Biological Engineering & Computing, 37
V. Schnabel (2001)
Mathematical models for magnetic stimulation of peripheral nerve
F. Behse (1990)
Morphometric studies on the human sural nerve.Acta neurologica Scandinavica. Supplementum, 132
P. Haninec (2004)
Undulating course of nerve fibres and bands of Fontana in peripheral nerves of the ratAnatomy and Embryology, 174
E. Zvěřina, L. Šprincl (1979)
[Fontana's spiral bands and undulating course of nerve fibers. Occurrence and clinical importance in man].Ceskoslovenska neurologie a neurochirurgie, 42 5
C. Byl, C. Puttlitz, N. Byl, Jeffery Lotz, K. Topp (2002)
Strain in the median and ulnar nerves during upper-extremity positioning.The Journal of hand surgery, 27 6
S. Sunderland (1990)
The anatomy and physiology of nerve injuryMuscle & Nerve, 13
E. Clarke, J. Bearn (1972)
Spiral nerve bands of Fontana.British Medical Journal, 2
N. Rijkhoff, J. Holsheimer, E. Koldewijn, J. Struijk, P. Kerrebroeck, F. Debruyne, H. Wijkstra (1994)
Selective stimulation of sacral nerve roots for bladder control: A study by computer modelingIEEE Transactions on Biomedical Engineering, 41
(1981)
Recruitment of motoneurons: the size principle', in DESMEDT, J. E. (Ed): 'Motor unit types, recruitment and plasticity in health and disease
(1979)
Fontana's spiral bands and undulating course of nerve fibres
The aim of the study was to investigate how variable fibre geometry influences the excitation and blocking threshold of an undulating peripheral nerve fibre. The sensitivity of the excitation and blocking thresholds of the nerve fibres to various geometric and stimulation parameters was examined. The nerve fibres had a spiral shape (defined by the undulation wavelength, undulation amplitude and phase), and the internodal length varied. Diameter-selective stimulation of nerve fibres was obtained using anodal block. Simulation was performed using a two-part simulation model: a volume conductor model to calculate the electrical potential distribution inside a tripolar cuff electrode and a model of a peripheral undulating human nerve fibre to simulate the fibre response to stimulation. The excitation threshold of the undulating fibres was up to 100% higher than the excitation threshold of the straight fibres. When a nerve was stimulated with long pulses, which are typically applied for anodal block (>400μs), the blocking threshold of the undulating fibres was up to four times higher than the blocking threshold of the straight fibres. Dependencies of the excitation threshold on geometric and stimulation parameters were the same as for a straight fibre. Dependencies of the blocking threshold on geometric and stimulation parameters were different compared with a straight fibre. Owing to the fibre undulation and variable internodal length, the blocking threshold and the minimum pulse duration to obtain anodal block were generally different in the proximal and distal directions. Owing to variable fibre geometry, the excitation threshold varied by up to ±40% of the mean value, and the blocking threshold varied by up to ±60% of the mean value. Owing to undulation, the blocking threshold of large fibres could be higher than the blocking threshold of small-diameter fibres, even if they had the same geometry. The results indicate that, during skeletal muscle stretching and contracting or during variation in joint angle, the excitation and blocking thresholds of the nerve fibres change owing to variations in fibre geometry. A straight fibre model could be too simple for modelling the response of peripheral nerve fibres to electrical stimulation.
Medical & Biological Engineering & Computing – Springer Journals
Published: Feb 22, 2006
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.