Access the full text.
Sign up today, get DeepDyve free for 14 days.
K. Jacobson, E. Sheets, Rudolf Simson (1995)
Revisiting the fluid mosaic model of membranes.Science, 268 5216
(1989)
Principles of optics, 6th ed
A. Ashkin, J. Dziedzic, J. Bjorkholm, S. Chu (1986)
Observation of a single-beam gradient force optical trap for dielectric particles.Optics letters, 11 5
M Born, E Wolf (1989)
Principles of opticsJ Chem Phys
J. Finer, R. Simmons, J. Spudich (1994)
Single myosin molecule mechanics: piconewton forces and nanometre stepsNature, 368
M. Allersma, F. Gittes, M. Decastro, R. Stewart, Christoph Schmidt (1998)
Two-dimensional tracking of ncd motility by back focal plane interferometry.Biophysical journal, 74 2 Pt 1
S. Block (1992)
Making light work with optical tweezersNature, 360
E‐L Florin, A Pralle, EHK Stelzer, JHK Hörber (1998)
Photonic force microscope calibration by thermal noise analysisRev Sci Instrum, 66
F. Gittes, C. Schmidt (1998)
Signals and noise in micromechanical measurements.Methods in cell biology, 55
Y. Sako, A. Nagafuchi, S. Tsukita, M. Takeichi, A. Kusumi (1998)
Cytoplasmic Regulation of the Movement of E-Cadherin on the Free Cell Surface as Studied by Optical Tweezers and Single Particle Tracking: Corralling and Tethering by the Membrane SkeletonThe Journal of Cell Biology, 140
Y. Sako, A. Kusumi (1994)
Compartmentalized structure of the plasma membrane for receptor movements as revealed by a nanometer-level motion analysisThe Journal of Cell Biology, 125
M. Brereton (1976)
Classical Electrodynamics (2nd edn)Physics Bulletin, 27
JD Jackson (1975)
Classical electrodynamicsJ Cell Biol
LP Ghislain, NA Switz, WW Webb (1994)
Measurement of small forces using an optical trapMethods Cell Biol, 65
J. Crocker (1997)
Measurement of the hydrodynamic corrections to the Brownian motion of two colloidal spheresJournal of Chemical Physics, 106
E. Florin, J. Hörber, E. Stelzer (1996)
High‐resolution axial and lateral position sensing using two‐photon excitation of fluorophores by a continuous‐wave Nd:YAG laserApplied Physics Letters, 69
L. Ghislain, N. Switz, W. Webb (1994)
Measurement of small forces using an optical trapReview of Scientific Instruments, 65
K. Svoboda, C. Schmidt, B. Schnapp, S. Block (1993)
Direct observation of kinesin stepping by optical trapping interferometryNature, 365
A Pralle, E‐L Florin, EHK Stelzer, JHK Hörber (1998)
Local viscosity probes by photonic force microscopyAnn Rev Biophys Biomol Struct, 66
E. Florin, Arnd Pralle, E. Stelzer, J. Hörber (1998)
Photonic force microscope calibration by thermal noise analysisApplied Physics A, 66
K. Svoboda, S. Block (1994)
Biological applications of optical forces.Annual review of biophysics and biomolecular structure, 23
Xin Tian, Chenhui Gao, Chongwei Wang, Xiaofan Zhao, Meng Wang, Xiaoming Xi, Zefeng Wang (2018)
PhotonicsFundamentals of Microfabrication and Nanotechnology, Three-Volume Set
JC Crocker (1997)
Measurement of the hydrodynamic corrections to the brownian motion of two colloidal spheresPhys Rev Lett, 106
S. Lin (1992)
Culturing nerve cellsCell, 69
John Crocker, David Grier (1994)
Microscopic measurement of the pair interaction potential of charge-stabilized colloid.Physical review letters, 73 2
G. Banker, K. Goslin (1998)
Culturing nerve cells
Arnd Pralle, E. Florin, E. Stelzer, J. Hörber (1998)
Local viscosity probed by photonic force microscopyApplied Physics A, 66
W. Denk, Watt Webb (1990)
Optical measurement of picometer displacements of transparent microscopic objects.Applied optics, 29 16
JC Crocker, DG Grier (1994)
A microscopic measurement of the pair interaction potential of charge‐stabilized colloidAppl Opt, 73
A quadrant photodiode placed in the back‐focal plane of the microscope of a laser trap provides a high‐resolution position sensor. We show that in addition to the lateral displacement of a trapped sphere, its axial position can be measured by the ratio of the intensity of scattered laser light to the total amount of the light reaching the detector. The addition of the axial information offers true three‐dimensional position detection in solution, creating, together with a position control, a photonic force microscope with nanometer spatial and microsecond temporal resolution. The measured position signals are explained as interference of the unscattered trapping laser beam with the laser light scattered by the trapped bead. Our model explains experimental data for trapped particles in the Rayleigh regime (radius a < 0.2λ) for displacements up to the focal dimensions. The cross‐talk between the signals in the three directions is explained and it is shown that this cross‐talk can be neglected for lateral displacements smaller than 75 nm and axial displacements below 150 nm. The advantages of three‐dimensional single‐particle tracking over conventional video‐tracking are shown through the example of the diffusion of the GPI‐anchored membrane protein Thy1.1 on a neurite. Microsc. Res. Tech. 44:378–386, 1999. © 1999 Wiley‐Liss, Inc.
Microscopy Research and Technique – Wiley
Published: Jan 1, 1999
Keywords: ; ; ; ; ; ;
Read and print from thousands of top scholarly journals.
Already have an account? Log in
Bookmark this article. You can see your Bookmarks on your DeepDyve Library.
To save an article, log in first, or sign up for a DeepDyve account if you don’t already have one.
Copy and paste the desired citation format or use the link below to download a file formatted for EndNote
Access the full text.
Sign up today, get DeepDyve free for 14 days.
All DeepDyve websites use cookies to improve your online experience. They were placed on your computer when you launched this website. You can change your cookie settings through your browser.